Our Services

Single Phase Testing

AS/NZS 3760 compliant testing for single-phase portable electrical appliances and equipment.

Overview

What is Single Phase Testing?

Single-phase testing covers the inspection and electrical safety testing of standard portable appliances that operate on 230V single-phase power — the most common type of electrical equipment found in Australian workplaces. This includes computers, monitors, printers, kettles, microwaves, power tools, extension leads, power boards, heaters, and more. Our technicians perform visual inspections, earth continuity tests, insulation resistance tests, and earth leakage tests using calibrated PAT equipment, ensuring every item meets AS/NZS 3760 requirements.

100%

AS/NZS 3760 Compliant

24hr

Report Delivery

Full

Digital Records

Local

Perth Team

Why It Matters

Why Single Phase Testing matters

Single-phase 230V appliances account for the vast majority of portable electrical equipment in Australian workplaces — and the majority of electrical test failures.

Under Work Health and Safety legislation, PCBUs must ensure all portable electrical equipment is maintained in a safe condition, regardless of whether it is single-phase or three-phase.

Single-phase equipment is often moved, unplugged, and re-plugged frequently, accelerating wear on plugs, cords, and connections.

Construction and demolition sites using single-phase equipment require 3-monthly testing under AS/NZS 3760 hostile-environment intervals.

A single faulty 230V appliance — a frayed cord, a cracked plug, or degraded insulation — can cause electric shock, fire, or electrocution.

Common Faults

What we commonly find

These are the most common faults found during single phase testing inspections in Perth workplaces.

Damaged power cords from frequent plugging and unplugging

Risk: Single-phase equipment is moved and unplugged more often than fixed equipment, accelerating cord and plug wear. Exposed conductors create an immediate risk of electric shock and fire.

Cord replaced on-site with correctly rated replacement, properly terminated with adequate strain relief, and item retested.

Cracked plug housings from impact or age

Risk: Live pins become accessible, creating a high risk of electric shock — especially in high-traffic areas like offices and kitchens.

Plug replaced with an approved heavy-duty replacement rated for the equipment's current draw.

Failed insulation resistance

Risk: Current leaking through degraded insulation can cause nuisance RCD tripping, equipment damage, or electric shock. Common in older equipment and items exposed to moisture or heat.

Item removed from service and documented. Repair or replacement recommended depending on equipment value and fault severity.

Overloaded power boards and extension leads

Risk: Daisy-chained power boards or overloaded extension leads cause overheating, melted housings, and fire. Common in office environments with limited outlets.

Overloaded configuration documented and flagged. Recommendations provided for additional circuits or redistribution of loads.

Testing intervals

Environment
Frequency
Construction & demolition sites
Every 3 months
Factories, warehouses, workshops
Every 6 months
Offices, hotels, retail
Every 12 months
AS/NZS 3760

Inspection & Testing Intervals

Recommended inspection and testing frequencies based on AS/NZS 3760 for different workplace environments and equipment types.

CAUTION

This information should be read together with the AS/NZS 3760 standard as a whole, particularly Clause 2.1. Inspection intervals vary depending on equipment type and operating environment.

Factories

Workshops, Places of repair, Manufacturing, Assembly, Maintenance, Fabrication

Industrial workplaces

Test & Tag

Every 6 Months

Port. Push Button

Daily / Before Every Use

Fix. Push Button

Every 6 Months

Port. Op. Time

Every 12 Months

Fix. Op. Time

Every 12 Months

Equipment where the flexible cord is subjected to flexing during normal use OR is open to abuse OR used in hostile environments.

Construction, mining, demolition, workshops

Test & Tag

Every 12 Months

Port. Push Button

Every 3 Months

Fix. Push Button

Every 6 Months

Port. Op. Time

Every 12 Months

Fix. Op. Time

Every 12 Months

Equipment where the supply flexible cord is NOT subjected to flexing in normal use and is NOT open to abuse and NOT used in hostile environments.

Office equipment

Test & Tag

Every 5 Years

Port. Push Button

Every 3 Months

Fix. Push Button

Every 6 Months

Port. Op. Time

Every 2 Years

Fix. Op. Time

Every 2 Years

Residential areas

Hotels, Motels, Boarding Houses, Accommodation, Residential Institutions

Residential & accommodation

Test & Tag

Every 2 Years

Port. Push Button

Every 6 Months

Fix. Push Button

Every 6 Months

Port. Op. Time

Every 2 Years

Fix. Op. Time

Every 2 Years

Equipment used for Commercial Cleaning

Cleaning contractors

Test & Tag

Every 6 Months

Port. Push Button

Daily / Before Every Use

Fix. Push Button

N/A

Port. Op. Time

Every 6 Months

Fix. Op. Time

N/A

Hire Equipment

Equipment supplied on hire

Inspection

Prior to Hire

Test & Tag

Every 3 Months

Push Button

Including push-button test by hirer

Port. Op. Time

Every 3 Months

Fix. Op. Time

Every 12 Months

Repaired, Serviced & Second-hand Equipment

After repair or service which could affect electrical safety, or before reintroduction into service, refer to AS/NZS 5762.

Important Note

Inspection frequencies depend on equipment type, condition and working environment. Hostile environments require more frequent inspection and testing.

Always refer to AS/NZS 3760 or contact our team if you are unsure which interval applies to your workplace.

Our Process

How Single Phase Testing works

Our streamlined process ensures every single phase testing engagement is efficient, thorough, and fully documented.

Step 01

Site Walk-Through

Our technician walks through your site to locate and identify all single-phase portable electrical equipment, including items in offices, kitchens, workshops, server rooms, and storage areas.

Step 02

Visual Inspection

Each item is visually inspected for damage to plugs, cords, casings, and connections. Items with visible damage are flagged before electrical testing begins.

Step 03

Electrical Testing

Calibrated PAT equipment runs earth continuity, insulation resistance, and earth leakage tests on each item. Test sequences are automated and results recorded digitally.

Step 04

Result & Tagging

Pass or fail result determined. A durable QR-coded tag is applied to each tested item. Failed items are tagged with a FAILED — DO NOT USE label and documented.

Step 05

Digital Reporting

Full compliance report with asset register, individual test results, pass/fail summary, and photos of failed items delivered to your online portal within 24 hours.

Inspection Checklist

What we inspect

Every Single Phase Testing inspection follows a rigorous checklist to ensure nothing is missed.

Visual Inspection

Plugs, cords, casings, strain reliefs, and connections checked for damage, wear, heat damage, or unauthorised modifications.

Earth Continuity

Verifies the protective earth connection is intact with low resistance, ensuring fault current can safely trip circuit protection.

Insulation Resistance

Measures insulation resistance between active/neutral conductors and earth at 500V DC to confirm no current leakage paths exist.

Earth Leakage

Measures leakage current flowing to earth during normal operation to verify it remains within safe limits.

RCD Push-Button Test

Where an RCD is present, verifies the safety switch trips correctly when the test button is pressed.

Tag Application

Durable, colour-coded QR-coded tag applied showing test date, pass/fail result, technician ID, and next scheduled test date.

What You Receive

After your inspection, you receive

These digital tools and reports are included as part of your inspection — not sold separately.

Digital Compliance Report

Full asset register with individual test results, pass/fail status, failure details with photographic evidence, and recommendations for non-compliant items.

QR Asset Labels

Each item receives a unique QR code linking to its complete test history, location, and next due date in your digital asset register.

Compliance Certificate

Formal certificate confirming your workplace meets AS/NZS 3760 requirements for all tested single-phase equipment.

Online Portal Access

24/7 access to your asset register, reports, compliance dashboard, and historical test data from any device.

Automated Reminders

Automatic reminders scheduled 30 days before each item is due for retest — so nothing slips through and you stay compliant.

Benefits

Why choose our Single Phase Testing?

Our single phase testingservice delivers measurable results for Perth businesses. Here's what sets us apart.

Comprehensive Testing

Full AS/NZS 3760 testing sequence — visual inspection, earth continuity, insulation resistance, and earth leakage on every item.

Minimal Disruption

Our technicians work around your schedule, testing items efficiently with minimal impact on your operations.

Digital Records

Every test result recorded in your digital asset register with QR-coded tags applied to each item.

Perth-Wide Coverage

Consistent single-phase testing service across all Perth suburbs and surrounding areas.

Industries

Industries we serve

Our single phase testing service is built for businesses across these industries.

Service Area

Where we provide this service

Our Single Phase Testing service is delivered onsite across the Perth metropolitan area and surrounding regions.

Single Phase Testing FAQs

Ready to Get Started?

Get a fast, obligation-free quote from Perth's trusted Test & Tag specialists.