Electrical Safety.
Tested. Tagged. Tracked.
Test & Tag is the process of inspecting, testing, and certifying electrical appliances to ensure workplace safety and regulatory compliance across Perth workplaces.

Electrical Appliance
Cord sets & extension leads

PAT Tester
Professional test equipment

PASS Tag
Dated compliance label

QR Asset Label
Scan for full test history
2,847
Assets
99.1%
Passed
12
Sites
Why Test & Tag?
Safety isn't optional.
It's the law.
Protect People
Prevent electrical injuries and fatalities by ensuring every appliance is safe before use.
Reduce Electrical Hazards
Identify faulty equipment before it causes fires, shocks, or equipment damage.
Meet AS/NZS 3760
Full compliance with Australian standards for in-service inspection and testing.
Digital Compliance
Real-time dashboards, automated reports, and complete audit trails for every asset.
How the Process Works
From inspection to digital compliance.
Every appliance follows the same five-step journey — from the bench to your compliance dashboard.
Equipment
Every electrical appliance is identified and logged into the system with a unique asset ID.
PAT Tester
Professional testing equipment checks earth continuity, insulation resistance, and polarity.
PASS Tag
A compliant safety tag is attached showing test results, date, and next inspection due.
QR Asset Label
A unique QR code links the physical asset to its digital compliance record.
Digital Record
Full inspection history, technician notes, and compliance status stored securely online.
Electrical Tests Explained
Six tests. One standard.
Every appliance undergoes a comprehensive testing regime as defined by AS/NZS 3760.
Visual Inspection
Physical condition of appliance, cable, plug, and connectors
Catches damage before it becomes a safety hazard
Technicians examine the entire appliance for signs of wear, damage, or deterioration including frayed cables, cracked plugs, and exposed wiring.
Earth Continuity Test
Resistance of the earth path from appliance to plug
Ensures fault current flows safely to earth, preventing electric shock
Measures the resistance of the protective earth conductor to ensure it can carry fault current safely.
Insulation Resistance Test
Insulation between live parts and earth
Detects degraded insulation before it causes short circuits or fires
Applies a test voltage to check that insulation resistance exceeds 1MΩ for Class I appliances.
Polarity Test
Correct wiring of live, neutral, and earth connections
Incorrect polarity can cause shocks and equipment damage
Verifies that the active and neutral conductors are connected to the correct terminals.
Leakage Current Test
Current leaking from appliance to earth
Excessive leakage can cause electric shock or trip RCDs
Measures the earth leakage current to ensure it falls within safe limits for the appliance class.
Functional Test
Appliance operates correctly under normal conditions
Confirms the appliance is safe and fit for intended use
Operates the appliance through its normal functions to verify safe operation.
Every Safety Test Explained
Understanding every electrical safety test.
During every Test & Tag inspection, multiple safety checks are performed depending on the equipment being tested. Each test has a specific purpose to help identify electrical faults and improve workplace safety.
Visual Inspection
Before any electrical testing begins
What it checks
Physical condition of appliance, cable, plug, and connectors
Why this test matters
Catches damage before it becomes a safety hazard — the first line of defence.
What happens if it fails
If damage is found, the appliance is immediately removed from service and tagged as failed. It cannot be reconnected until repaired or replaced.
You receive
Earth Continuity Test
Confirming the safety path to earth
What it checks
Resistance of the earth path from appliance to plug
Why this test matters
Ensures fault current flows safely to earth, preventing electric shock.
What happens if it fails
A failed earth continuity test means the protective earth path is broken. The appliance poses a serious shock risk and must not be used.
You receive
Insulation Resistance Test
Verifying protective insulation integrity
What it checks
Insulation between live parts and earth
Why this test matters
Detects degraded insulation before it causes short circuits or fires.
What happens if it fails
Low insulation resistance indicates current is leaking through degraded insulation. The appliance must be removed from service immediately.
You receive
Polarity Test
Ensuring correct wiring connections
What it checks
Correct wiring of active, neutral, and earth conductors
Why this test matters
Incorrect polarity can cause electric shocks, equipment damage, and fire.
What happens if it fails
Incorrectly wired appliances can energise metal parts or bypass protective devices. The appliance must be rewired before reuse.
You receive
Leakage Current Test
Measuring unwanted electrical current
What it checks
Current leaking from appliance to earth during operation
Why this test matters
Excessive leakage can cause electric shock or nuisance tripping of safety switches.
What happens if it fails
High leakage current indicates insulation breakdown or component failure. The appliance requires repair or replacement.
You receive
RCD Testing
Verifying safety switch performance
What it checks
Trip time and trip current of residual current devices
Why this test matters
Confirms safety switches disconnect power quickly enough to prevent fatal electric shock.
What happens if it fails
An RCD that trips too slowly or not at all cannot protect against electric shock. It must be replaced immediately.
You receive
Test Outcomes
PASS or FAIL. No grey areas.
Every appliance receives a clear result against AS/NZS 3760. There is no partial compliance.
PASS
Equipment is safe to use
- Equipment remains in service
- Receives a compliance tag with test date
- Added to your digital compliance records
- Next retest date assigned
- QR label applied for instant identification
FAIL
Equipment is not safe to use
- Equipment is immediately removed from service
- Tagged with a FAIL label and date
- Repair or replacement required
- Must be retested before reuse
- Recorded in compliance documentation
What You Receive
Your compliance, digitally delivered.
After testing, every result is securely stored so you can access your inspection history whenever required.
QR Asset Label
Every tested appliance receives a unique QR label. Scan it to instantly view its complete inspection history.
Compliance Report
A detailed PDF report with asset register, test results, and recommendations — ready for audits.
Photo Evidence
Photos of any issues found during inspection, attached to the asset's compliance record.
Inspection History
Complete timeline of every test, every result, every technician visit — stored permanently.
Compliance Certificate
Official documentation confirming your workplace meets AS/NZS 3760 requirements.
Understanding Results
PASS or FAIL. Know instantly.
PASS
Appliance is safe to use
Test & Tag Aussie
PASS
Next Test
12 Jan 2027
FAIL
Appliance must be removed
Test & Tag Aussie
FAIL
Action
Remove
Your Complete Compliance Journey
Everything is digitally organised for you.
After every inspection, your compliance information is securely stored and immediately available whenever you need it.
QR Asset Label Applied
Every tested appliance receives a unique QR code label. Scan it to instantly view its full inspection history, test results, and compliance status.
Permanent label, scanned anytimeInspection Results Uploaded
Results are synchronised immediately after testing — earth continuity, insulation resistance, polarity, and all test data captured on-site.
Real-time sync, no delaysCompliance Report Generated
Audit-ready reports are generated automatically with asset registers, individual test results, pass/fail status, and recommendations.
PDF delivered to your inboxCertificates Ready
Official compliance documentation confirming your workplace meets AS/NZS 3760 requirements — available instantly after testing.
Download or share anytimeCustomer Portal Updated
Inspection history, certificates, and upcoming due dates are securely stored online — accessible 24/7 from any device.
Secure, always availableNext Test Reminder Scheduled
Automatic reminders are scheduled before your next inspection is due — so you never miss a compliance deadline.
Never miss a retest dateQR Asset Label Applied
Every tested appliance receives a unique QR code label. Scan it to instantly view its full inspection history, test results, and compliance status.
Permanent label, scanned anytimeInspection Results Uploaded
Results are synchronised immediately after testing — earth continuity, insulation resistance, polarity, and all test data captured on-site.
Real-time sync, no delaysCompliance Report Generated
Audit-ready reports are generated automatically with asset registers, individual test results, pass/fail status, and recommendations.
PDF delivered to your inboxCertificates Ready
Official compliance documentation confirming your workplace meets AS/NZS 3760 requirements — available instantly after testing.
Download or share anytimeCustomer Portal Updated
Inspection history, certificates, and upcoming due dates are securely stored online — accessible 24/7 from any device.
Secure, always availableNext Test Reminder Scheduled
Automatic reminders are scheduled before your next inspection is due — so you never miss a compliance deadline.
Never miss a retest dateInspection & Testing Intervals
Recommended inspection and testing frequencies based on AS/NZS 3760 for different workplace environments and equipment types.
CAUTION
This information should be read together with the AS/NZS 3760 standard as a whole, particularly Clause 2.1. Inspection intervals vary depending on equipment type and operating environment.
| Type of Environment and/or Equipment | Test & Tag (Class I, Class II, Cord Sets, Extension Leads, EPODs) | Interval Between Inspection and Tests | |||
|---|---|---|---|---|---|
| Residual Current Devices (RCDs) — Push Button Test by User | Residual Current Devices (RCDs) — Operating Time & Push Button Test | ||||
| Portable (c) | Fixed (d) | Portable (e) | Fixed (f) | ||
Factories Workshops, Places of repair, Manufacturing, Assembly, Maintenance, Fabrication Industrial workplaces | Every 6 Months | Daily / Before Every Use | Every 6 Months | Every 12 Months | Every 12 Months |
Equipment where the flexible cord is subjected to flexing during normal use OR is open to abuse OR used in hostile environments. Construction, mining, demolition, workshops | Every 12 Months | Every 3 Months | Every 6 Months | Every 12 Months | Every 12 Months |
Equipment where the supply flexible cord is NOT subjected to flexing in normal use and is NOT open to abuse and NOT used in hostile environments. Office equipment | Every 5 Years | Every 3 Months | Every 6 Months | Every 2 Years | Every 2 Years |
Residential areas Hotels, Motels, Boarding Houses, Accommodation, Residential Institutions Residential & accommodation | Every 2 Years | Every 6 Months | Every 6 Months | Every 2 Years | Every 2 Years |
Equipment used for Commercial Cleaning Cleaning contractors | Every 6 Months | Daily / Before Every Use | N/A | Every 6 Months | N/A |
Hire Equipment Equipment supplied on hire Inspection | Prior to Hire | Including push-button test by hirer before hire | N/A | N/A | |
Hire Equipment Equipment supplied on hire Test & Tag | Every 3 Months | N/A | N/A | Every 3 Months | Every 12 Months |
Repaired, Serviced & Second-hand Equipment Before return to service | After repair or service which could affect electrical safety, or before reintroduction into service, refer to AS/NZS 5762. | ||||
Factories
Workshops, Places of repair, Manufacturing, Assembly, Maintenance, Fabrication
Industrial workplaces
Test & Tag
Every 6 MonthsPort. Push Button
Daily / Before Every UseFix. Push Button
Every 6 MonthsPort. Op. Time
Every 12 MonthsFix. Op. Time
Every 12 MonthsEquipment where the flexible cord is subjected to flexing during normal use OR is open to abuse OR used in hostile environments.
Construction, mining, demolition, workshops
Test & Tag
Every 12 MonthsPort. Push Button
Every 3 MonthsFix. Push Button
Every 6 MonthsPort. Op. Time
Every 12 MonthsFix. Op. Time
Every 12 MonthsEquipment where the supply flexible cord is NOT subjected to flexing in normal use and is NOT open to abuse and NOT used in hostile environments.
Office equipment
Test & Tag
Every 5 YearsPort. Push Button
Every 3 MonthsFix. Push Button
Every 6 MonthsPort. Op. Time
Every 2 YearsFix. Op. Time
Every 2 YearsResidential areas
Hotels, Motels, Boarding Houses, Accommodation, Residential Institutions
Residential & accommodation
Test & Tag
Every 2 YearsPort. Push Button
Every 6 MonthsFix. Push Button
Every 6 MonthsPort. Op. Time
Every 2 YearsFix. Op. Time
Every 2 YearsEquipment used for Commercial Cleaning
Cleaning contractors
Test & Tag
Every 6 MonthsPort. Push Button
Daily / Before Every UseFix. Push Button
N/APort. Op. Time
Every 6 MonthsFix. Op. Time
N/AHire Equipment
Equipment supplied on hire
Inspection
Prior to HireTest & Tag
Every 3 MonthsPush Button
Including push-button test by hirer
Port. Op. Time
Every 3 MonthsFix. Op. Time
Every 12 MonthsRepaired, Serviced & Second-hand Equipment
After repair or service which could affect electrical safety, or before reintroduction into service, refer to AS/NZS 5762.
Important Note
Inspection frequencies depend on equipment type, condition and working environment. Hostile environments require more frequent inspection and testing.
Always refer to AS/NZS 3760 or contact our team if you are unsure which interval applies to your workplace.
Digital Compliance
Your compliance, digitized.
Real-time dashboards, automated reports, and complete audit trails for every asset across every site.
0
Total Assets
0
Passed
0
Due Soon
0%
Compliance
Monthly Compliance
Recent Activity
Head Office — 3 assets tested
2 min agoWarehouse — RCD test completed
15 min agoRegional — 2 items due soon
1 hr agoOverall Compliance
99.1%
Industries
Trusted across every industry.
Construction
3-monthly testing for hostile environments
Schools
Holiday testing with Working with Children checks
Healthcare
Zero disruption to patient care
Hospitality
Kitchen and front-of-house testing
Warehouses
Forklift chargers and conveyor systems
Offices
Annual compliance for workplace assets
FAQ
Common questions.
Ready to simplify electrical compliance?
Get a free consultation and discover how Test & Tag Aussie can keep your workplace safe and compliant.
AS/NZS 3760
Compliant
Full
Digital Records
24hr
Report Turnaround
Digital
Compliance Portal