Our RCD testing service verifies that your Residual Current Devices (safety switches) are functioning correctly and will protect your workers from electric shock. We perform push-button tests and operating time measurements per AS/NZS 3760. RCDs can disconnect power in as little as 30 milliseconds, and regular testing ensures they will activate when needed most.
100%
AS/NZS 3760 Compliant
24hr
Report Delivery
Full
Digital Records
Local
Perth Team
Why It Matters
Why RCD Testing matters
RCDs can disconnect power in as little as 30 milliseconds — fast enough to save a life.
RCD testing is mandatory under WHS legislation for all Australian workplaces.
A faulty RCD gives a false sense of security while providing zero protection.
Regular testing is the only way to confirm an RCD will work when needed most.
Common Faults
What we commonly find
These are the most common faults found during rcd testing inspections in Perth workplaces.
Slow trip time
Risk: RCD disconnects too slowly to prevent electrocution.
RCD removed from service and replaced.
Failure to trip
Risk: RCD provides zero protection despite appearing functional.
RCD removed from service immediately.
Nuisance tripping
Risk: RCD trips during normal operation, causing disruption.
RCD tested and replaced if defective.
Incorrect wiring
Risk: RCD may not detect earth leakage correctly.
Wiring corrected and RCD retested.
Testing intervals
Inspection & Testing Intervals
Recommended inspection and testing frequencies based on AS/NZS 3760 for different workplace environments and equipment types.
CAUTION
This information should be read together with the AS/NZS 3760 standard as a whole, particularly Clause 2.1. Inspection intervals vary depending on equipment type and operating environment.
| Type of Environment and/or Equipment | Test & Tag (Class I, Class II, Cord Sets, Extension Leads, EPODs) | Interval Between Inspection and Tests | |||
|---|---|---|---|---|---|
| Residual Current Devices (RCDs) — Push Button Test by User | Residual Current Devices (RCDs) — Operating Time & Push Button Test | ||||
| Portable (c) | Fixed (d) | Portable (e) | Fixed (f) | ||
Factories Workshops, Places of repair, Manufacturing, Assembly, Maintenance, Fabrication Industrial workplaces | Every 6 Months | Daily / Before Every Use | Every 6 Months | Every 12 Months | Every 12 Months |
Equipment where the flexible cord is subjected to flexing during normal use OR is open to abuse OR used in hostile environments. Construction, mining, demolition, workshops | Every 12 Months | Every 3 Months | Every 6 Months | Every 12 Months | Every 12 Months |
Equipment where the supply flexible cord is NOT subjected to flexing in normal use and is NOT open to abuse and NOT used in hostile environments. Office equipment | Every 5 Years | Every 3 Months | Every 6 Months | Every 2 Years | Every 2 Years |
Residential areas Hotels, Motels, Boarding Houses, Accommodation, Residential Institutions Residential & accommodation | Every 2 Years | Every 6 Months | Every 6 Months | Every 2 Years | Every 2 Years |
Equipment used for Commercial Cleaning Cleaning contractors | Every 6 Months | Daily / Before Every Use | N/A | Every 6 Months | N/A |
Hire Equipment Equipment supplied on hire Inspection | Prior to Hire | Including push-button test by hirer before hire | N/A | N/A | |
Hire Equipment Equipment supplied on hire Test & Tag | Every 3 Months | N/A | N/A | Every 3 Months | Every 12 Months |
Repaired, Serviced & Second-hand Equipment Before return to service | After repair or service which could affect electrical safety, or before reintroduction into service, refer to AS/NZS 5762. | ||||
Factories
Workshops, Places of repair, Manufacturing, Assembly, Maintenance, Fabrication
Industrial workplaces
Test & Tag
Every 6 MonthsPort. Push Button
Daily / Before Every UseFix. Push Button
Every 6 MonthsPort. Op. Time
Every 12 MonthsFix. Op. Time
Every 12 MonthsEquipment where the flexible cord is subjected to flexing during normal use OR is open to abuse OR used in hostile environments.
Construction, mining, demolition, workshops
Test & Tag
Every 12 MonthsPort. Push Button
Every 3 MonthsFix. Push Button
Every 6 MonthsPort. Op. Time
Every 12 MonthsFix. Op. Time
Every 12 MonthsEquipment where the supply flexible cord is NOT subjected to flexing in normal use and is NOT open to abuse and NOT used in hostile environments.
Office equipment
Test & Tag
Every 5 YearsPort. Push Button
Every 3 MonthsFix. Push Button
Every 6 MonthsPort. Op. Time
Every 2 YearsFix. Op. Time
Every 2 YearsResidential areas
Hotels, Motels, Boarding Houses, Accommodation, Residential Institutions
Residential & accommodation
Test & Tag
Every 2 YearsPort. Push Button
Every 6 MonthsFix. Push Button
Every 6 MonthsPort. Op. Time
Every 2 YearsFix. Op. Time
Every 2 YearsEquipment used for Commercial Cleaning
Cleaning contractors
Test & Tag
Every 6 MonthsPort. Push Button
Daily / Before Every UseFix. Push Button
N/APort. Op. Time
Every 6 MonthsFix. Op. Time
N/AHire Equipment
Equipment supplied on hire
Inspection
Prior to HireTest & Tag
Every 3 MonthsPush Button
Including push-button test by hirer
Port. Op. Time
Every 3 MonthsFix. Op. Time
Every 12 MonthsRepaired, Serviced & Second-hand Equipment
After repair or service which could affect electrical safety, or before reintroduction into service, refer to AS/NZS 5762.
Important Note
Inspection frequencies depend on equipment type, condition and working environment. Hostile environments require more frequent inspection and testing.
Always refer to AS/NZS 3760 or contact our team if you are unsure which interval applies to your workplace.
Our Process
How RCD Testing works
Our streamlined process ensures every rcd testing engagement is efficient, thorough, and fully documented.
RCD Location
Our technician identifies all RCDs on site — switchboard-mounted, portable, and in-line.
Visual Inspection
Each RCD is visually inspected for damage, correct wiring, and mounting condition.
Push-Button Test
The test button is pressed to verify basic trip functionality.
Operating Time Test
Calibrated RCD tester measures the exact trip time at rated residual current levels.
Results & Labelling
Pass or fail result recorded. RCD labelled with test date and next due date.
Digital Reporting
Full RCD test report with trip times, locations, and pass/fail status delivered within 24 hours.
Inspection Checklist
What we inspect
Every RCD Testing inspection follows a rigorous checklist to ensure nothing is missed.
Push-Button Test
Verifies the RCD trips when the test button is pressed, confirming basic functionality.
Operating Time Test
Measures the exact time taken for the RCD to disconnect at rated residual current.
Non-Trip Test
Tests at half-rated current to verify the RCD does not nuisance trip during normal operation.
Wiring Condition
Visual inspection of RCD wiring, connections, and mounting.
Label & Documentation
RCD labelled with test date, result, and next test due date.
Compliance Recording
All test results recorded in your digital compliance report.
What You Receive
After your inspection, you receive
These digital tools and reports are included as part of your inspection — not sold separately.
RCD Test Report
Detailed report with trip times, test conditions, and pass/fail status for every RCD.
Compliance Certificate
Formal certificate confirming all RCDs meet AS/NZS 3760 requirements.
RCD Location Register
Complete register of all RCDs with locations, types, and test history.
Online Portal Access
24/7 access to RCD test results and compliance status.
Automated Reminders
Email alerts when RCDs are approaching their next test due date.
Benefits
Why choose our RCD Testing?
Our rcd testingservice delivers measurable results for Perth businesses. Here's what sets us apart.
Life-Saving Protection
RCDs are the single most effective device for preventing electrocution. Regular testing ensures they work when needed.
Legal Compliance
RCD testing is required under WHS legislation and AS/NZS 3760 for all Perth workplaces.
Push-Button & Operating Time Tests
We perform both user-level push-button tests and precision operating time measurements with calibrated equipment.
Detailed Documentation
Every RCD test is recorded with trip times, test conditions, and pass/fail status in your compliance report.
Industries
Industries we serve
Our rcd testing service is built for businesses across these industries.
Service Area
Where we provide this service
Our RCD Testing service is delivered onsite across the Perth metropolitan area and surrounding regions.
Perth Metropolitan
Peel Region
Regional WA
- Selected regional locations available by arrangement
- Enquire for Availability
RCD Testing FAQs
Related Services
Other services you may need
Ready to Get Started?
Get a fast, obligation-free quote from Perth's trusted Test & Tag specialists.